AFTER LOSE LARGE CAPACITY PART 2 3D TLC8T23



HI
THIS IS SP BLAZE B10 64B
The quality has dropped this year
OLD TIME AGO YOU PAY TO SP AND BUY ORGINAL MLC AND GOOD CONTROLER
BY THE WAY FLASH STOP WORKING AN SECOND DAY OF LIFE
LETS GO AND FIND THE PROBLEM

CONTROLER IS 2309 WITH OUT ANY COIL AND EVEN DP DM FUSE


WHAT IS THE COIL?

13 комментариев

I CHECK 5 VOLT FUSE AND BETWEEN GND AND VCC MULTIMETER SHOW 640
SO 5VOLT FINE >The problem is not the customer SYSTEM

3.3 VOLT IS GONE
PROBLEM IS PCB Low cost Stupid design
FOR 64GB?? LOW COST PCB? IN USB3?
This is a betrayal
EVEN IS917 HAVE 3.3 VOLT COIL
PART 2=>NAND NAND IS DOWNRADED TOSHIBA 3D TLC
HV=LOW PE PROGRAM ERAE TIME AND BAD BLOCK TOO MANY
PART 3
TRY USE 3D SUPPORT CONTROLER FOR NAND
I FOUND AU6998SN-GTC
IN FEW DAY I WRITE RESULT PLASE WAIT...


EXTRACT 2 NAND HVJ6MFG AND INSTALL ON ALCOR
AND DO JUMPER MOD
HAVE FUN
Technology without spirituality makes our world so ugly