Please help with A-Data S102 Pro 64GB - SMI 3261

I have the drive

Controller: Silicon Motion SM3261 AAS
Possible Memory Chip(s):
Intel 29F32B08MCMF2 *2
Intel 29F32B08MCMF3 *2
Memory Type: MLC
Flash ID: 8984643C
Flash CE: 2+2
Flash Channels: Dual
Chip F/W: ISP 121022-1AB
VID: 090C
PID: 3261
Manufacturer: A-Data
Product: 64GB
Query Vendor ID: A-Data
Query Product ID: USB DISK
Query Product Revision: 1100
Physical Disk Capacity: 66873982976 Bytes
Windows Disk Capacity: 0 Bytes
Internal Tags: 8S2F-AAGJ

The USB drive is no longer recognized by the PC — it show only USB mass storage device or SMI Factory Driver in the Device manager — depend from the driver. The SMI MPtool not recognize the drive at all even with the factory driver.
I used smi_mptool_v2.5.03_v3_l1130v2_3261aa_3261ab
Please help me…
  • avatar
  • 0

4 комментария

Old Frimware has a Crashed And Cant ReFrimwared

So Do Not Use Factory Driver

Direct Connect +5 Or 29+30 pin
Before Insert To Computer Direct Connect Flash Memory (Nand Chip )29+30 pin after

Must Be Adata Change To USB MEMORY BAR

And After See The Drive In smitest.exe Leave The 29,30 pin
7 pin of Flash is (IO)INPOUT OUTPUT DATA

SO YOUR DATA HAS A CRASHED AND MAKE HANG SYSTEM AND SMITEST.EXE CANT FIND DRIVE

SO CUT THE 2 OR 3 OR CONNECT +5 TO CHANGE MEMORY ID FOR EXAMPLE

89 45 32 22==>>04 04 04 04
AFTER SMI FIND IT BRAKE THE DIRECT CONNECT CLICK REFLESH AND DO THAT
Thanks to all of you people! This site is amazing! Thanks for the all information!